Source code for RsCmwWcdmaMeas.Implementations.MultiEval_.Trace_.Phd_.Current

from typing import List

from .....Internal.Core import Core
from .....Internal.CommandsGroup import CommandsGroup
from .....Internal.ArgSingleSuppressed import ArgSingleSuppressed
from .....Internal.Types import DataType


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class Current: """Current commands group definition. 2 total commands, 0 Sub-groups, 2 group commands""" def __init__(self, core: Core, parent): self._core = core self._base = CommandsGroup("current", core, parent)
[docs] def fetch(self) -> List[float]: """SCPI: FETCh:WCDMa:MEASurement<instance>:MEValuation:TRACe:PHD:CURRent \n Snippet: value: List[float] = driver.multiEval.trace.phd.current.fetch() \n Returns the values of the phase discontinuity traces for up to 120 slots. One value per measured slot is returned (see method RsCmwWcdmaMeas.Configure.MultiEval.msCount) . INTRO_CMD_HELP: The meaning of the value depends on the measurement period (see method RsCmwWcdmaMeas.Configure.MultiEval.Mperiod.modulation) : \n - For full-slot measurements, each value indicates the phase discontinuity at the boundary between a slot and the previous slot. As there is no previous slot for slot 0, the first returned phase discontinuity value equals NCAP. - For half-slot measurements, each value indicates the phase discontinuity at the boundary between the first and second half-slot of a slot. This value can be measured for all slots, including slot 0. See also 'Detailed Views: Phase Discontinuity' \n Use RsCmwWcdmaMeas.reliability.last_value to read the updated reliability indicator. \n :return: phase_disc: float One value per measured slot Range: -180 deg to 180 deg, Unit: deg""" suppressed = ArgSingleSuppressed(0, DataType.Integer, False, 1, 'Reliability') response = self._core.io.query_bin_or_ascii_float_list_suppressed(f'FETCh:WCDMa:MEASurement<Instance>:MEValuation:TRACe:PHD:CURRent?', suppressed) return response
[docs] def read(self) -> List[float]: """SCPI: READ:WCDMa:MEASurement<instance>:MEValuation:TRACe:PHD:CURRent \n Snippet: value: List[float] = driver.multiEval.trace.phd.current.read() \n Returns the values of the phase discontinuity traces for up to 120 slots. One value per measured slot is returned (see method RsCmwWcdmaMeas.Configure.MultiEval.msCount) . INTRO_CMD_HELP: The meaning of the value depends on the measurement period (see method RsCmwWcdmaMeas.Configure.MultiEval.Mperiod.modulation) : \n - For full-slot measurements, each value indicates the phase discontinuity at the boundary between a slot and the previous slot. As there is no previous slot for slot 0, the first returned phase discontinuity value equals NCAP. - For half-slot measurements, each value indicates the phase discontinuity at the boundary between the first and second half-slot of a slot. This value can be measured for all slots, including slot 0. See also 'Detailed Views: Phase Discontinuity' \n Use RsCmwWcdmaMeas.reliability.last_value to read the updated reliability indicator. \n :return: phase_disc: float One value per measured slot Range: -180 deg to 180 deg, Unit: deg""" suppressed = ArgSingleSuppressed(0, DataType.Integer, False, 1, 'Reliability') response = self._core.io.query_bin_or_ascii_float_list_suppressed(f'READ:WCDMa:MEASurement<Instance>:MEValuation:TRACe:PHD:CURRent?', suppressed) return response