Current¶
SCPI Commands
FETCh:WCDMa:MEASurement<Instance>:MEValuation:TRACe:PHD:CURRent
READ:WCDMa:MEASurement<Instance>:MEValuation:TRACe:PHD:CURRent
- class Current[source]
Current commands group definition. 2 total commands, 0 Sub-groups, 2 group commands
- fetch() → List[float][source]
# SCPI: FETCh:WCDMa:MEASurement<instance>:MEValuation:TRACe:PHD:CURRent value: List[float] = driver.multiEval.trace.phd.current.fetch()
Returns the values of the phase discontinuity traces for up to 120 slots. One value per measured slot is returned (see method RsCmwWcdmaMeas.Configure.MultiEval.msCount) .
INTRO_CMD_HELP: The meaning of the value depends on the measurement period (see method RsCmwWcdmaMeas.Configure.MultiEval.Mperiod.modulation) :
For full-slot measurements, each value indicates the phase discontinuity at the boundary between a slot and the previous slot. As there is no previous slot for slot 0, the first returned phase discontinuity value equals NCAP.
For half-slot measurements, each value indicates the phase discontinuity at the boundary between the first and second half-slot of a slot. This value can be measured for all slots, including slot 0.
See also ‘Detailed Views: Phase Discontinuity’
Use RsCmwWcdmaMeas.reliability.last_value to read the updated reliability indicator.
- return
phase_disc: float One value per measured slot Range: -180 deg to 180 deg, Unit: deg
- read() → List[float][source]
# SCPI: READ:WCDMa:MEASurement<instance>:MEValuation:TRACe:PHD:CURRent value: List[float] = driver.multiEval.trace.phd.current.read()
Returns the values of the phase discontinuity traces for up to 120 slots. One value per measured slot is returned (see method RsCmwWcdmaMeas.Configure.MultiEval.msCount) .
INTRO_CMD_HELP: The meaning of the value depends on the measurement period (see method RsCmwWcdmaMeas.Configure.MultiEval.Mperiod.modulation) :
For full-slot measurements, each value indicates the phase discontinuity at the boundary between a slot and the previous slot. As there is no previous slot for slot 0, the first returned phase discontinuity value equals NCAP.
For half-slot measurements, each value indicates the phase discontinuity at the boundary between the first and second half-slot of a slot. This value can be measured for all slots, including slot 0.
See also ‘Detailed Views: Phase Discontinuity’
Use RsCmwWcdmaMeas.reliability.last_value to read the updated reliability indicator.
- return
phase_disc: float One value per measured slot Range: -180 deg to 180 deg, Unit: deg