Current

SCPI Commands

FETCh:WCDMa:MEASurement<Instance>:TPC:CARRier<Carrier>:TRACe:UEPower:CURRent
READ:WCDMa:MEASurement<Instance>:TPC:CARRier<Carrier>:TRACe:UEPower:CURRent
CALCulate:WCDMa:MEASurement<Instance>:TPC:CARRier<Carrier>:TRACe:UEPower:CURRent
class Current[source]

Current commands group definition. 3 total commands, 0 Sub-groups, 3 group commands

calculate(carrier=<Carrier.Default: -1>)List[float][source]
# SCPI: CALCulate:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:TRACe:UEPower:CURRent
value: List[float] = driver.tpc.carrier.trace.uePower.current.calculate(carrier = repcap.Carrier.Default)

Return the values of the UE power vs slot trace per carrier. You can query the number of measured slots using the CONFigure:WCDMa:MEAS:TPC:…:MLENgth? command of the used measurement mode. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

Use RsCmwWcdmaMeas.reliability.last_value to read the updated reliability indicator.

param carrier

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return

ue_power: float N power results, one per measured slot Range: -100 dBm to 55 dBm, Unit: dBm

fetch(carrier=<Carrier.Default: -1>)List[float][source]
# SCPI: FETCh:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:TRACe:UEPower:CURRent
value: List[float] = driver.tpc.carrier.trace.uePower.current.fetch(carrier = repcap.Carrier.Default)

Return the values of the UE power vs slot trace per carrier. You can query the number of measured slots using the CONFigure:WCDMa:MEAS:TPC:…:MLENgth? command of the used measurement mode. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

Use RsCmwWcdmaMeas.reliability.last_value to read the updated reliability indicator.

param carrier

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return

ue_power: float N power results, one per measured slot Range: -100 dBm to 55 dBm, Unit: dBm

read(carrier=<Carrier.Default: -1>)List[float][source]
# SCPI: READ:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:TRACe:UEPower:CURRent
value: List[float] = driver.tpc.carrier.trace.uePower.current.read(carrier = repcap.Carrier.Default)

Return the values of the UE power vs slot trace per carrier. You can query the number of measured slots using the CONFigure:WCDMa:MEAS:TPC:…:MLENgth? command of the used measurement mode. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

Use RsCmwWcdmaMeas.reliability.last_value to read the updated reliability indicator.

param carrier

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return

ue_power: float N power results, one per measured slot Range: -100 dBm to 55 dBm, Unit: dBm