Average

SCPI Commands

READ:WCDMa:MEASurement<Instance>:TPC:CARRier<Carrier>:PSTeps:AVERage
FETCh:WCDMa:MEASurement<Instance>:TPC:CARRier<Carrier>:PSTeps:AVERage
CALCulate:WCDMa:MEASurement<Instance>:TPC:CARRier<Carrier>:PSTeps:AVERage
class Average[source]

Average commands group definition. 3 total commands, 0 Sub-groups, 3 group commands

class CalculateStruct[source]

Response structure. Fields:

  • Reliability: int: decimal ‘Reliability Indicator’

  • Pwr_Steps_0_Db: float: No parameter help available

  • Pwr_Steps_B_1_Db: float: No parameter help available

  • Pwr_Steps_Cm_1_Db: float: No parameter help available

  • Pwr_Steps_Group_A: float: No parameter help available

  • Pwr_Steps_Group_B: float: No parameter help available

  • Pwr_Steps_Group_C: float: No parameter help available

  • Start_Slot_Group_A: float: No parameter help available

  • Pwr_Steps_Eg: float: No parameter help available

  • Pwr_Steps_Fh: float: No parameter help available

  • Pwr_Steps_Group_Eg: float: No parameter help available

  • Pwr_Steps_Group_Fh: float: No parameter help available

  • Start_Slot_Group_Eg: float: No parameter help available

  • Start_Slot_Group_Fh: float: No parameter help available

  • Pwr_Steps_Up: float: No parameter help available

  • Pwr_Steps_Down: float: No parameter help available

  • Epwr_Steps_B_1_D_B: enums.ResultStatus2: No parameter help available

  • Epwr_Steps_Cm_1_D_B: enums.ResultStatus2: No parameter help available

  • Epwr_Steps_Eg: enums.ResultStatus2: No parameter help available

  • Epwr_Steps_Fh: enums.ResultStatus2: No parameter help available

class ResultData[source]

Response structure. Fields:

  • Reliability: int: decimal ‘Reliability Indicator’

  • Pwr_Steps_0_Db: float: No parameter help available

  • Pwr_Steps_B_1_Db: float: No parameter help available

  • Pwr_Steps_Cm_1_Db: float: No parameter help available

  • Pwr_Steps_Group_A: float: No parameter help available

  • Pwr_Steps_Group_B: float: No parameter help available

  • Pwr_Steps_Group_C: float: No parameter help available

  • Start_Slot_Group_A: int: No parameter help available

  • Pwr_Steps_Eg: float: No parameter help available

  • Pwr_Steps_Fh: float: No parameter help available

  • Pwr_Steps_Group_Eg: float: No parameter help available

  • Pwr_Steps_Group_Fh: float: No parameter help available

  • Start_Slot_Group_Eg: int: No parameter help available

  • Start_Slot_Group_Fh: int: No parameter help available

  • Pwr_Steps_Up: float: No parameter help available

  • Pwr_Steps_Down: float: No parameter help available

  • Init_Pwr_Step: float: No parameter help available

  • Rpwr_Steps: float: No parameter help available

  • Rpwr_Steps_Group: float: No parameter help available

  • Pwr_Step_Ncm_Cm: float: No parameter help available

  • Pwr_Step_Cm_Ncm: float: No parameter help available

  • Epwr_Steps_B_1_D_B: float: No parameter help available

  • Epwr_Steps_Cm_1_D_B: float: No parameter help available

  • Epwr_Steps_Eg: float: No parameter help available

  • Epwr_Steps_Fh: float: No parameter help available

calculate(carrier=<Carrier.Default: -1>)CalculateStruct[source]
# SCPI: CALCulate:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:PSTeps:AVERage
value: CalculateStruct = driver.tpc.carrier.psteps.average.calculate(carrier = repcap.Carrier.Default)

Return the power step and power step group single value results per carrier. The minimum, maximum and average results can be retrieved. The command returns all parameters listed below, independent of the selected TPC setup. However, only for some of the parameters measured values are available. For the other parameters, only an indicator is returned (e.g. NAV) . ‘Step A’ to ‘step H’ refer to the test steps of the ‘Inner Loop Power Control’ mode (results <2_Step0dB_ABC> to <14_StartFH> and <22_EPStepsB1dB> to <25_EPStepsFH>) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

param carrier

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return

structure: for return value, see the help for CalculateStruct structure arguments.

fetch(carrier=<Carrier.Default: -1>)ResultData[source]
# SCPI: FETCh:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:PSTeps:AVERage
value: ResultData = driver.tpc.carrier.psteps.average.fetch(carrier = repcap.Carrier.Default)

Return the power step and power step group single value results per carrier. The minimum, maximum and average results can be retrieved. The command returns all parameters listed below, independent of the selected TPC setup. However, only for some of the parameters measured values are available. For the other parameters, only an indicator is returned (e.g. NAV) . ‘Step A’ to ‘step H’ refer to the test steps of the ‘Inner Loop Power Control’ mode (results <2_Step0dB_ABC> to <14_StartFH> and <22_EPStepsB1dB> to <25_EPStepsFH>) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

param carrier

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return

structure: for return value, see the help for ResultData structure arguments.

read(carrier=<Carrier.Default: -1>)ResultData[source]
# SCPI: READ:WCDMa:MEASurement<instance>:TPC:CARRier<carrier>:PSTeps:AVERage
value: ResultData = driver.tpc.carrier.psteps.average.read(carrier = repcap.Carrier.Default)

Return the power step and power step group single value results per carrier. The minimum, maximum and average results can be retrieved. The command returns all parameters listed below, independent of the selected TPC setup. However, only for some of the parameters measured values are available. For the other parameters, only an indicator is returned (e.g. NAV) . ‘Step A’ to ‘step H’ refer to the test steps of the ‘Inner Loop Power Control’ mode (results <2_Step0dB_ABC> to <14_StartFH> and <22_EPStepsB1dB> to <25_EPStepsFH>) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

param carrier

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return

structure: for return value, see the help for ResultData structure arguments.