Current¶
SCPI Commands
FETCh:WCDMa:MEASurement<Instance>:MEValuation:LIST:SPECtrum:ACLR:P<Plus>:CURRent
- class Current[source]
Current commands group definition. 1 total commands, 0 Sub-groups, 1 group commands
- fetch(aclr_mode: Optional[RsCmwWcdmaMeas.enums.AclrMode] = None, plus=<Plus.Default: -1>) → List[float][source]
# SCPI: FETCh:WCDMa:MEASurement<instance>:MEValuation:LIST:SPECtrum:ACLR:P<nr>:CURRent value: List[float] = driver.multiEval.listPy.spectrum.aclr.p.current.fetch(aclr_mode = enums.AclrMode.ABSolute, plus = repcap.Plus.Default)
- Return the power of the adjacent channels for all measured list mode segments.
INTRO_CMD_HELP: The adjacent channel selected via M<no>/P<no> is at the following frequency relative to the carrier frequency:
M1 = -5 MHz, M2 = -10 MHz
P1 = +5 MHz, P2 = +10 MHz
Use RsCmwWcdmaMeas.reliability.last_value to read the updated reliability indicator.
- param aclr_mode
ABSolute | RELative ABSolute: ACLR power displayed in dBm as absolute value RELative: ACLR power displayed in dB relative to carrier power
- param plus
optional repeated capability selector. Default value: Ch1 (settable in the interface ‘P’)
- return
aclr: float Comma-separated list of values, one per measured segment Range: -100 dBm to 55 dBm, Unit: dBm