OcInfo

SCPI Commands

READ:WCDMa:MEASurement<Instance>:MEValuation:CARRier<Carrier>:RCDerror:OCINfo
FETCh:WCDMa:MEASurement<Instance>:MEValuation:CARRier<Carrier>:RCDerror:OCINfo
class OcInfo[source]

OcInfo commands group definition. 2 total commands, 0 Sub-groups, 2 group commands

class ResultData[source]

Response structure. Fields:

  • Reliability: int: decimal ‘Reliability Indicator’

  • State: List[enums.State]: OFF | VAR | ON State of the channel OFF: Channel off since start of measurement VAR: Channel has been on and off ON: Channel on since start of measurement

  • Spreading_Factor: List[enums.SpreadingFactorB]: No parameter help available

  • Modulation: List[enums.Modulation]: BPSK | 4PAM | 4PVar Modulation type of the channel BPSK: Constantly BPSK modulated 4PAM: Constantly 4PAM modulated 4PVar: BPSK and 4PAM occurred

fetch(carrier=<Carrier.Default: -1>)ResultData[source]
# SCPI: FETCh:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:RCDerror:OCINfo
value: ResultData = driver.multiEval.carrier.rcdError.ocInfo.fetch(carrier = repcap.Carrier.Default)
Returns the overall channel information for the RCDE measurement. This information is determined from all measured slots.

INTRO_CMD_HELP: The parameters <State>, <SpreadFactor> and <Modulation> are returned for the individual channels:

  • Values 2 to 4: DPCCH

  • Values 5 to 7: DPDCH

  • Values 8 to 10: HSDPCCH

  • Values 11 to 13: EDPCCH

  • Values 14 to 16: EDPDCH1

  • Values 17 to 19: EDPDCH2

  • Values 20 to 22: EDPDCH3

  • Values 23 to 25: EDPDCH4

param carrier

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return

structure: for return value, see the help for ResultData structure arguments.

read(carrier=<Carrier.Default: -1>)ResultData[source]
# SCPI: READ:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:RCDerror:OCINfo
value: ResultData = driver.multiEval.carrier.rcdError.ocInfo.read(carrier = repcap.Carrier.Default)
Returns the overall channel information for the RCDE measurement. This information is determined from all measured slots.

INTRO_CMD_HELP: The parameters <State>, <SpreadFactor> and <Modulation> are returned for the individual channels:

  • Values 2 to 4: DPCCH

  • Values 5 to 7: DPDCH

  • Values 8 to 10: HSDPCCH

  • Values 11 to 13: EDPCCH

  • Values 14 to 16: EDPDCH1

  • Values 17 to 19: EDPDCH2

  • Values 20 to 22: EDPDCH3

  • Values 23 to 25: EDPDCH4

param carrier

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)

return

structure: for return value, see the help for ResultData structure arguments.