Average¶
SCPI Commands
READ:WCDMa:MEASurement<Instance>:MEValuation:CARRier<Carrier>:CDPower:AVERage
FETCh:WCDMa:MEASurement<Instance>:MEValuation:CARRier<Carrier>:CDPower:AVERage
- class Average[source]
Average commands group definition. 2 total commands, 0 Sub-groups, 2 group commands
- class ResultData[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability Indicator’
Dpcch: float: float RMS CDP values for the indicated channels Range: -100 dB to 0 dB (SDEViation 0 dB to 50 dB) , Unit: dB
Dpdch: float: float RMS CDP values for the indicated channels Range: -100 dB to 0 dB (SDEViation 0 dB to 50 dB) , Unit: dB
Hsdpcch: float: float RMS CDP values for the indicated channels Range: -100 dB to 0 dB (SDEViation 0 dB to 50 dB) , Unit: dB
Edpcch: float: float RMS CDP values for the indicated channels Range: -100 dB to 0 dB (SDEViation 0 dB to 50 dB) , Unit: dB
Edpdch_1: float: float RMS CDP values for the indicated channels Range: -100 dB to 0 dB (SDEViation 0 dB to 50 dB) , Unit: dB
Edpdch_2: float: float RMS CDP values for the indicated channels Range: -100 dB to 0 dB (SDEViation 0 dB to 50 dB) , Unit: dB
Edpdch_3: float: float RMS CDP values for the indicated channels Range: -100 dB to 0 dB (SDEViation 0 dB to 50 dB) , Unit: dB
Edpdch_4: float: float RMS CDP values for the indicated channels Range: -100 dB to 0 dB (SDEViation 0 dB to 50 dB) , Unit: dB
- fetch(carrier=<Carrier.Default: -1>) → ResultData[source]
# SCPI: FETCh:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:CDPower:AVERage value: ResultData = driver.multiEval.carrier.cdPower.average.fetch(carrier = repcap.Carrier.Default)
Returns the RMS CDP vs. slot values measured in a selected slot. In addition to the current values, average, minimum, maximum and standard deviation values can be retrieved.
- param carrier
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)
- return
structure: for return value, see the help for ResultData structure arguments.
- read(carrier=<Carrier.Default: -1>) → ResultData[source]
# SCPI: READ:WCDMa:MEASurement<instance>:MEValuation:CARRier<carrier>:CDPower:AVERage value: ResultData = driver.multiEval.carrier.cdPower.average.read(carrier = repcap.Carrier.Default)
Returns the RMS CDP vs. slot values measured in a selected slot. In addition to the current values, average, minimum, maximum and standard deviation values can be retrieved.
- param carrier
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Carrier’)
- return
structure: for return value, see the help for ResultData structure arguments.